Ingersoll Rand air compressor tells you - the inverter's ten protection knowledge of the motor

Views : 2187
Author : Runningway
Update time : 2019-03-25 09:14:53
We all know that the inverter adjusts the voltage and frequency of the output power supply by the internal IGBT breaking, and supplies the required power supply voltage according to the actual needs of the motor, thereby achieving the purpose of energy saving and speed regulation. What are the ways and measures for the inverter to protect the motor? Let Xiaobian take everyone to see it!

1. Overvoltage protection The output of the inverter has a voltage detection function. The inverter can automatically adjust the output voltage so that the motor does not withstand overvoltage and the motor runs within the set voltage range.

2. Undervoltage protection When the voltage of the motor is lower than 90% of the normal voltage (some settings are 85%), the inverter protection stops.

3. Overcurrent protection When the current of the motor exceeds 150%/3 seconds of the rated value, or 200%/10 microseconds of the rated current, the inverter protects the motor by stopping.

4. The phase loss protection monitors the output voltage. When the output is out of phase, the inverter will alarm and the inverter will stop immediately to protect the motor.

5, anti-phase protection Inverter can be set so that the motor can only rotate in one direction, can not set the direction of rotation, unless the user changes the phase sequence of the motor A, B, C wiring, otherwise there is no possibility of inversion.

6. Overload protection The inverter monitors the motor current. When the motor current exceeds 120%/1 minute of the set rated current, the inverter protects the motor by stopping.

7. Grounding protection The inverter is equipped with a special grounding protection circuit, which is generally composed of a grounding protection transformer and a relay. When one or two phases are grounded, the inverter stops immediately. Of course, if the user requests, we can also design to protect the shutdown immediately after grounding.

8. Short-circuit protection After the output of the inverter is short-circuited, it will inevitably cause over-current. In 10 microseconds, the inverter will stop the motor to protect the motor.
Related News
Can air compressor lubricating oil be mixed?
Feb .20.2023
Can you mix lubricating oil? Many people think that there is no big problem with the mixed use of lubricating oil, but in actual cases, there are many problems caused by the hasty mixed use of lubricating oil, so it is very important to understand the kno
Top Ten Top Compressor Manufacturing Powers In The World
Oct .20.2022
Top Ten Top Compressor Manufacturing Powers In The World
Why Do Air Compressors Need Staged Compression? Can't You Compress It Once?
Oct .09.2022
Many people know that the two stages of the compressor are suitable for producing high pressure, and the first stage is suitable for producing large amount of air. Sometimes, you need to perform more than two compression operations. Why do you need to per