Facebook
Categories

Oil-free air compressor failure: comprehensive failure analysis

Nov 30th,2020 2808 Views
Air compressors often fail. If the following failures occur, don't worry, first try to use the experience of Yiju service personnel to troubleshoot step by step:

The compressor does not supply air:
1) Check whether the control cylinder is moving, and check whether the butterfly valve has mechanical failure;
2) Check whether the loading solenoid has suction;
3) Check the sub-circuits where the solenoid valve is located one by one.

The compressor cannot be started:
1) Check whether there is a control voltage, if not, check whether the fuse is intact;
2) Check whether the control relay and time relay operate normally.

The compressor runs normally, and it is difficult to start after stopping:
1) The brand of lubricant used is wrong, and the oil should be changed thoroughly after cleaning;
2) If the oil is sticky and coking, the oil should be changed thoroughly after cleaning;
3) The shaft seal is seriously leaking. Remove and replace;
4) The original position of the unloading valve disc changes, and the position is readjusted.

The compressor does not start smoothly, and it will automatically stop after a few seconds:
1) Check whether the automatic air switch has taken off and whether the voltage is normal, which should be eliminated;
2) Whether the closing degree of the intake butterfly valve is normal, it should be checked and adjusted or replaced;
3) Check whether the three phases of the contactor and the motor are normal during Y-△ startup.