Company News

What is the reason for the excessive water in the oil-free air compressor?

Views : 768
Author : Runningway
Update time : 2020-12-30 14:25:58
Many users who use oil-free air compressors have encountered it. In the rainy season or typhoon season, they complained that there is water in the air compressor equipment in the factory no matter how they are maintained and treated. Many users have installed drying equipment, but in reality The effect is still the same, the system still has water. Oil-free screw 55-90 1​

In fact, installing drying equipment to remove moisture from the air compressor is just a drainage method. Although it can effectively reduce the moisture in the system, if it is suitable for rainy, rainy, typhoon seasons, long rains, and humid air , It needs timely inspection and maintenance to ensure the dryness of the air compressor.
 
The first reason is the rainy weather. The equipment is in humid air, and the air contains more moisture than normal weather conditions. The compressed gas when the equipment is working is vaporized inside the equipment and passes through the exhaust port at the high temperature inside the equipment. The temperature will drop after exiting the equipment, and the vaporized water will liquefy into water droplets; this kind of weather cannot be changed, but the equipment can be changed. Before using the air compressor equipment every day, the liquefied water in the equipment will be timely Perform emptying.

Secondly, the installation of the drying equipment must be matched with the air compressor system, and the drying strength needs to meet the system requirements. If the system requirements cannot be met, the air will still carry a lot of moisture; at the same time, check whether the drying equipment is working properly, whether it is invalid or malfunctioning If it is such a reason, repair it. Then check the air storage to see if the water inside the container is drained clean.

If none of the above reasons exist, recheck the installation of the air compressor system. If the installation of the oil-free air compressor system is unreasonable and the wastewater cannot be discharged in time, there will be water no matter how you adjust it.
Related News
Can air compressor lubricating oil be mixed?
Feb .20.2023
Can you mix lubricating oil? Many people think that there is no big problem with the mixed use of lubricating oil, but in actual cases, there are many problems caused by the hasty mixed use of lubricating oil, so it is very important to understand the kno
Top Ten Top Compressor Manufacturing Powers In The World
Oct .20.2022
Top Ten Top Compressor Manufacturing Powers In The World
Why Do Air Compressors Need Staged Compression? Can't You Compress It Once?
Oct .09.2022
Many people know that the two stages of the compressor are suitable for producing high pressure, and the first stage is suitable for producing large amount of air. Sometimes, you need to perform more than two compression operations. Why do you need to per