After the screw air compressor unit is equipped with a dryer, there is still a lot of water in the unit system. I believe that many users who use air compressors have encountered this problem. The following is an analysis for everyone.

In the post-processing equipment of screw air compressors, there are mainly air tanks, dryers and filters. The dry compressed air can ensure the unimpeded operation of the air system and production process of the air compressor.

The function of the dryer is to eliminate the condensed water in the compressed air and ensure the discharge of dry and clean compressed air. After equipped with the relevant dryer, but the compressed air still contains water, this is because of these reasons.

1. The air humidity around the air compressor station is too high
The air itself has humidity and a certain amount of moisture. When the air is compressed, due to the high temperature inside the compressor, the moisture directly evaporates to form water vapor, which is then discharged from the compressor according to the pressure. When the compressor is stopped, the temperature drops, causing water vapor. Condensate is formed. Therefore, the humidity of the working environment of the air compressor should be low, or the condensed water should be drained before starting to use.

2. Failure of post-processing drying equipment
Generally, the post-drying capacity of a cold dryer is a pressure dew point of 3°C. If your working site temperature is lower than 3°C, there must be water. At this time, it is recommended to configure the post-treatment drying equipment with a micro-heat suction dryer, and the pressure dew point can reach -20°C without water in it.

3. The post-processing drying equipment equipped with the air compressor has insufficient capacity
Generally speaking, the post-drying treatment capacity configured by the manufacturer for users is configured according to the average air consumption. If your instantaneous air consumption is large, the capacity of the post-treatment drying equipment will be insufficient, resulting in water in the air.

4. The gas storage tank itself has the function of water accumulation
There was a lot of water in it and it was not discharged, so I forgot to drain it. Open the drain valve under the gas tank regularly to drain the water.
Related News
Can air compressor lubricating oil be mixed?
Feb .20.2023
Can you mix lubricating oil? Many people think that there is no big problem with the mixed use of lubricating oil, but in actual cases, there are many problems caused by the hasty mixed use of lubricating oil, so it is very important to understand the kno
Top Ten Top Compressor Manufacturing Powers In The World
Oct .20.2022
Top Ten Top Compressor Manufacturing Powers In The World
Why Do Air Compressors Need Staged Compression? Can't You Compress It Once?
Oct .09.2022
Many people know that the two stages of the compressor are suitable for producing high pressure, and the first stage is suitable for producing large amount of air. Sometimes, you need to perform more than two compression operations. Why do you need to per